    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

low lubricity oval flow sensor

Date:2018-01-03 source:

  low lubricity oval flow sensor   email: porter@microflowmeter.com

Shanghai JSN Micro Flow MeterCO.,LTD is a manufactory  for Super MicroLiquid Flow Meter,Oval gear flow meter ,Mass Flow Meter,Circle Spur Gear FlowMeter,Gear Pump,Gear metering Pump etc. The company is a professional companyfor the production and supporting of automated instruments. It has strongtechnical force. The scientific research personnel account for more than 40% ofthe company"s total number of people. The production equipment is excellent andthe processing capability is strong. Since the new aviation instrument has anew and old research team, it not only produces the general-purpose flowmeasurement instrument in the market can also be designed and processedaccording to the user"s requirements in accordance with the user"s requirementsto solve the user"s various demands on the flow measurement.

 low lubricity oval flow sensor

low lubricity oval flow sensor

Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.

TheCX-M and G-series mirco flow meters are the world"s new volumetric flowmetersintroduced by BASF in 2011. Since its establishment, the CX-M oval gear flowmeter and the G-series mirco flow meters have been selling well in the marketfor more than 100,000 units a year since they were sold. The third generationlaunched in 2017, with more than 90% accuracy and stability, won thecertification of the National Bureau of Metrology. The quality and reliabilityof Shanghai JiShen instruments need not worry. According to the statistics ofChina Instrument Association, Deep flow meter reliability has always beenranked in the top 3, especially in the long-term statistics failure rate is farbelow the industry average, deep advocate "the best after-sales service isno service", but also achieved a continuous three years without qualitycomplaints .

oval flow sensor

low lubricity oval flow sensor

The Ovalgear flow meter is a volumetric flow meter. The metering chamber is composed ofupper and lower end caps. The shell is formed by an oval gear rotor. The gearrotor meshes with the rotating shaft to convey the fluid. The permanent magnetarranged in the rotor is used for the detection of the rotor rotation. Twosensor holes are placed on the upper end to cover the detection sensor. Asealing ring is installed between the housing and the upper and lower end capsto prevent leakage of the measurement fluid. The base depth flowmeter is madeof a material with high wear resistance so that the flowmeter Can guaranteehigh precision measurement within the long service life.

 low lubricity oval flow sensor

low lubricity oval flow sensor


Item

model

K-factor

The minimum flow

Flow range

Connection size

Gear flow meter

CX-G0.025-P-AL

0.025ml

0.001L/Min

0.004~1 L/min

G1/8

gear flow meter

CX-G0.025-P-SS

0.025ml

0.001L/Min

0.004~1 L/min

G1/8

gear flow meter

CX-G0.04-P-AL

0.04ml

0.004L/min

0.01~2L/min

G1/4

gear flow meter

CX-G0.04-P-SS

0.04ml

0.004L/min

0.01~2L/min

G1/4

gear flow meter

CX-G0.1-P-AL

0.1ml

0.008L/min

0.02~4L/min

G3/8

gear flow meter

CX-G0.1-P-SS

0.1ml

0.008L/min

0.02~4L/min

G3/8

gear flow meter

CX-G0.2-P-AL

0.245ml

0.01L/Min

0.08~8L/min

G3/8

gear flow meter

CX-G0.2-P-SS

0.245ml

0.01L/Min

0.08~8L/min

G3/8

gear flow meter

CX-G0.4-P-AL

0.4ml

0.01L/Min

0.1~20L/min

G1/2

gear flow meter

CX-G0.4-P-SS

0.4ml

0.01L/Min

0.1~20L/min

G1/2

gear flow meter

CX-G1-P-AL

1ml

0.02L/Min

0.2~40L/min

G1/2

gear flow meter

CX-G1-P-SS

1ml

0.02L/Min

0.2~40L/min

G1/2

gear flow meter

CX-G2-P-AL

2ml

0.04L/Min

0.5-60L/min

G3/4

gear flow meter

CX-G2-P-SS

2ml

0.04L/Min

0.5-60L/min

G3/4

Remark: Hightemperature, high pressure, high frequency, special connection, specialmaterials, two-way measurement, etc. can be customized


What are the precautions for the gear flow meter?

1) In the field installation, it should be noted that the direction of the arrow on the flow meter housing is consistent with the flow direction of the fluid;

2) The flowmeter is installed on the same pipe with the same nominal internal diameter as the inlet and outlet fittings. When the pipe is connected with the flowmeter, the seal should not protrude into the fluid;

3) The fluid to be measured shall be filled with the metering room of the flowmeter and the connecting pipes before and after it. If the fluid to be measured contains gas, a gas separator shall be installed before the flowmeter and the filter;